Watts are speed, watt-hours are the fuel tank

The formula: runtime (hours) ≈ usable Wh ÷ average watts

The honest adjustment: usable Wh ≈ rated Wh × 0.85. The inverter that converts battery power to household AC loses roughly 10–15%, and no plan should end at absolute zero. If a runtime claim doesn't mention losses, it used the full nameplate number — discount it.

The catch: most appliances don't draw their label watts

The formula needs average watts, and that's where people go wrong. Three patterns cover most of the house:

Typical appliance draws (for planning)

ApplianceDraw while onPlanning figure
Full-size fridge100–250 W, cycling~1.1 kWh/day (standard) — use your EnergyGuide
CPAP11–59 W depending on humidifier89–472 Wh per night (ResMed AirSense 10 data)
Sump pump ⅓ HP / ½ HP~800 W / ~1,050 W + surgeWatts × minutes-per-hour ÷ 60
Wi-Fi router + modem~10 W~240 Wh/day if left on
LED light bulb~10 W each4 bulbs × 5 evening hours ≈ 200 Wh
TV (modern LED)~80–150 W~120 W × hours watched
Phone charging~10–20 W~15–25 Wh per full charge
Laptop~30–65 W in use~50 W × work hours
Microwave~1,000–1,200 W15 min of use ≈ 250–300 Wh
Coffee maker~800–1,200 W while brewingOne brew cycle ≈ 60–100 Wh
Space heater~1,500 W~1,500 Wh per hour — see the warning below

Fridge, CPAP, and pump figures are from the manufacturer/EnergyGuide sources cited on their dedicated pages. The rest are typical published ranges for common models, checked November 2026 — fine for planning, and your own appliances' labels beat any table.

The worksheet: size a station for your outage

Step 1 — list what must run, and for how long, in a 24-hour outage day. (Fridge: 24h. CPAP: 8h. Lights: 5h. Router: 24h or only waking hours — your call.)

Step 2 — convert each to Wh per day using the patterns above: steady loads watts × hours; cycling loads from daily energy figures; motors from minutes-per-hour.

Step 3 — add it up, then divide by 0.85. That's the rated capacity you need per day of outage.

Step 4 — check the watts, not just the watt-hours: add up everything that could run at the same moment, and confirm the station's continuous output covers it — and its surge rating covers the biggest motor's start.

Step 5 — decide your days. Multiply by the outage length you want to cover, or plan on solar recharging to cover the daily total (a panel array roughly equal to your daily Wh in rated watts, in decent sun, is the usual starting estimate — see the cost guide).

A worked example: a realistic essentials list

LoadMathWh per day
Standard fridgeEnergyGuide ~1.1 kWh/day1,100
CPAP, humidifier on low~28 W × 8 h~221
Wi-Fi router10 W × 16 h (off overnight)160
4 LED lights40 W × 5 h200
2 phones + laptop top-upflat estimate~100
Total~1,781 Wh/day

1,781 ÷ 0.85 ≈ 2,095Wh of rated capacity per outage day — which is why the ~2kWh class is the home-backup sweet spot: it covers a realistic essentials list for a day, and a fridge-plus-CPAP-only list for considerably longer. A ~1kWh station covers the same list for about half a day, or a trimmed list (fridge + lights, CPAP moved to its own small station) overnight. Neither is "wrong" — it depends which day of the outage you're planning for.